Spacez insight · April 2026 · 6 min read
Office Fitout Technology & Infrastructure Guide Melbourne
The most expensive technology mistake in office fitouts is treating IT and AV as an afterthought — something to "sort out later." In practice, the technology…
Why Technology Planning Must Start at Brief Stage
The most expensive technology mistake in office fitouts is treating IT and AV as an afterthought — something to "sort out later." In practice, the technology requirements drive structural decisions made early in the design process:
- Cable pathways must be coordinated with ceiling, floor, and wall systems — you can't run conduit through a finished plasterboard ceiling without opening it up
- Server room location affects HVAC design (dedicated cooling), structural loading, and data backbone routing
- Power requirements for AV and IT equipment must be reflected in electrical design from the start
- Wireless access point locations need to be coordinated with ceiling layout
- Acoustic requirements for meeting rooms are driven partly by video conferencing use
Technology planning should happen in parallel with architectural design, not after it.
Structured Cabling and Data Infrastructure
Category 6A vs Category 6 Cabling
Modern Melbourne offices are moving toward Cat 6A as the standard for new fitouts. Cat 6A supports 10 Gigabit Ethernet at full 100m runs — future-proofing the install for at least 10–15 years.
When to specify Cat 6A:
- Any fitout that will include video conferencing, large file transfers, or cloud-intensive workflows
- Offices with 30+ staff where bandwidth demands will grow
- Technology companies, creative agencies, and financial services
When Cat 6 is sufficient:
- Small offices (under 15 staff) with modest IT requirements
- Short-term tenancies or budget-constrained fitouts
Cabling Outlet Density
A common mistake is under-specifying outlets. The modern hybrid workplace creates unpredictable desk usage — you need enough outlets to support any desk configuration, including quiet areas, collaboration zones, and hot-desk banks.
Rule of thumb: 2 data outlets per workstation position minimum; 4 per fixed desk. Meeting rooms: 4 data outlets plus 2 USB charging points at minimum per room.
Patch Panels and Communications Rooms
Every office fitout needs a communications room or at minimum a lockable communications cabinet. Size it correctly from the start:
| Office Size | Communications Infrastructure |
|---|---|
| Under 20 staff | Wall-mounted 12–24U data cabinet |
| 20–50 staff | Dedicated 9–12 sqm comms room with cooling |
| 50–150 staff | Server room 12–25 sqm with redundant cooling |
| 150+ staff | Purpose-built server room, consider colocation for primary systems |
Fibre Optic Backbone
For multi-floor fitouts or long horizontal runs (over 90m), specify fibre optic backbone cable between communications rooms. Fibre is now cost-effective and eliminates the distance limitation of copper.
Wireless Network Infrastructure
Modern offices are as dependent on reliable Wi-Fi as they are on mains power. Planning wireless infrastructure requires:
Access Point Placement
Wi-Fi access points must be placed for coverage AND capacity. In high-density environments (open-plan floors, training rooms, boardrooms), you need more access points spaced closer together, each handling fewer devices.
Coverage planning rules:
- Aim for one access point per 100–150 sqm in open-plan areas
- One dedicated access point in every meeting room with 8+ seats
- Access points above finished ceiling (concealed) — specify plenum-rated cable and ceiling-mounted housing in the fitout drawings
PoE (Power over Ethernet)
Wireless access points, IP phones, and security cameras all run on Power over Ethernet. Your electrical design must account for PoE switch power requirements in the communications room.
Network Segmentation
Modern offices typically need at least three separate wireless networks:
- Corporate network: Staff devices, full network access
- Guest network: Internet access only, isolated from corporate
- IoT network: Smart building devices, building management systems
Your fitout should include conduit provisions for separate cable runs if your business has security requirements that demand physical network separation.
Audio-Visual (AV) Systems
AV infrastructure is now a core productivity tool, not an optional extra. Planning AV into the fitout from the start produces better outcomes at lower cost than retrofitting.
Meeting Room AV
Every meeting room in a modern Melbourne office needs:
Small meeting room (2–4 people):
- Wall-mounted display (65–75 inch)
- Integrated video conferencing camera and microphone system (Microsoft Teams or Zoom certified)
- Wireless presentation capability (Barco ClickShare or similar)
- 4x data outlets, power, and HDMI (specify power and signal cable runs in fitout)
Medium meeting room (6–10 people):
- Large format display (86–98 inch) or dual displays
- Ceiling-mounted 360° conference camera OR front-of-room camera plus ceiling mic array
- Room booking panel integrated with Microsoft 365 or Google Workspace
Boardroom (12–20 people):
- Dual display or video wall system
- Distributed audio: in-ceiling speakers with zoned control
- Camera system covering full table depth
- Acoustic design to manage reverberation (RT60 target: 0.4–0.6 seconds)
Presentation and Collaboration Spaces
Training rooms and all-hands spaces need:
- Projection or large-format LED display
- Wireless presentation system
- In-ceiling distributed audio
- Lectern or presentation station
Lobby and Reception AV
Brand presence in reception areas increasingly uses digital displays:
- Digital signage screens (portrait or landscape) for brand content
- Visitor management tablet integration
- Video calling capability for remote receptionists
Smart Building Systems
Modern Melbourne fitouts increasingly incorporate building automation and IoT technology:
Environmental Controls
- Smart HVAC: Occupancy-based thermostat control (reduce energy use in unoccupied areas)
- Automated blinds: Glare and heat control integrated with lighting management
- CO2 monitoring: Automated ventilation response to occupancy levels (particularly relevant post-COVID)
Lighting Automation
LED lighting with DALI or DMX control allows:
- Occupancy-based lighting (motion sensors turn off lights in empty areas)
- Daylight harvesting (reduce artificial lighting near windows based on natural light levels)
- Scene presets for different space uses (work, presentation, cleaning)
- Integration with building management system (BMS)
Access Control
Modern access control goes beyond a card reader on the front door:
- Mobile credentials (phone-based access, no physical card required)
- Zone-based access control (restrict areas by staff group)
- Integration with visitor management
- Time-based access (after-hours lockout)
Desk and Room Booking
Hot-desking environments require booking systems integrated with the physical space:
- Physical desk sensors (occupancy detection) or app-based booking
- Meeting room booking panels at each room entrance
- Analytics dashboard showing utilisation by zone, time, and day
Common Technology Infrastructure Mistakes in Melbourne Office Fitouts
1. Under-specifying power
Technology infrastructure consumes significant power. Specify dedicated circuits for server rooms, UPS systems for critical equipment, and enough GPOs at every workstation.
2. No pathway coordination
Running cable through a finished ceiling or wall costs 3–5x what it costs during fitout. Plan conduit, cable trays, and pathways before the ceiling goes up.
3. Forgetting future expansion
Run spare conduit and pull strings in cable pathways for future runs. It costs almost nothing during fitout but saves significant money when you expand.
4. Wrong room acoustics for video conferencing
Rooms that look great can sound terrible on video calls. Specify acoustic panels, ceiling finishes, and soft furnishings to achieve RT60 targets in meeting rooms.
5. Ignoring the comms room environment
Server rooms need dedicated cooling (not shared with the general HVAC system), appropriate power distribution, and cable management. Overlooking these adds cost and creates ongoing operational problems.
Fitout Cost: Technology Infrastructure Budget Guide
| Technology Category | Typical Cost Range |
|---|---|
| Structured cabling (Cat 6A, per outlet) | $250–$450 installed |
| Wireless infrastructure (per AP, installed) | $800–$1,500 |
| Meeting room AV (small room) | $8,000–$18,000 |
| Meeting room AV (medium room) | $18,000–$40,000 |
| Boardroom AV system | $40,000–$150,000+ |
| Access control (per door) | $1,500–$4,000 |
| Smart lighting control (per zone) | $1,500–$5,000 |
For a 500 sqm office fitout with 4 meeting rooms, a server room, and standard smart office features, budget $80,000–$180,000 for technology infrastructure. This represents roughly 8–15% of total fitout cost.
How Spacez Coordinates Technology in Office Fitouts
At Spacez, technology coordination is embedded in our fitout process:
- Technology brief at project start: We work with your IT team (or appoint a technology consultant) to define requirements before design commences
- Coordinated design documentation: AV, data, and electrical requirements are coordinated in the fitout drawings — no conflict between trades
- Approved technology subcontractors: We work with experienced AV and data contractors who understand commercial fitout requirements
- Technology commissioning: Systems are tested and handed over with full documentation before practical completion
Start Your Technology-Ready Office Fitout
Planning an office fitout in Melbourne and want to get the technology right from day one? Contact Spacez for a free consultation. We'll help you plan a workspace that's built for how your business operates today — and ready for what comes next.
Spacez delivers office, retail, medical, and hospitality fitouts across Melbourne. Learn more about our office fitout services.